QRR0.01G Hot Aerosol Fire Extinguishing Device | Automatic Fire Suppression for Electrical Panels
₨ 2,000 Original price was: ₨ 2,000.₨ 1,550Current price is: ₨ 1,550.
The QRR0.01G Hot Aerosol Fire Extinguishing Device is a compact automatic fire suppression solution designed to protect electrical panels, control cabinets, and enclosed equipment from fire hazards. Using aerosol-based fire suppression technology, it helps extinguish developing fires without water or pressurized gas cylinders, making it suitable for designated electrical and industrial fire protection applications.
- Automatic Fire Suppression: Designed for fire protection in suitable enclosed spaces.
- Hot Aerosol Technology: Generates a fire-suppressing aerosol to interrupt the combustion process.
- Fast Discharge Time: Activation/discharge time of ≤15 seconds.
- 10-Year Service Life: Designed for long-term use under specified conditions.
- Wide Operating Temperature Range: Suitable for -50°C to +90°C.
- 100 g/m³ Extinguishing Density: Specified aerosol extinguishing density.
- Compact & Maintenance-Free Design: Space-saving construction without pressurized cylinders.
- Electrical Equipment Protection: Intended for electrical panels, control cabinets, and enclosed machinery.
- European Standards: Supplier-stated compliance with EN 15276-1:2019 and EN 15276-2:2019.
Fast Shipping
Carrier information
20k products
Payment methods
24/7 Support
Unlimited help desk
2-day Delivery
Track or off orders
The QRR0.01G Hot Aerosol Fire Extinguishing Device is an advanced fire suppression solution engineered for use in enclosed electrical and industrial environments. Designed to help control developing fire incidents, this compact automatic aerosol fire suppression device is suitable for protecting electrical panels, control cabinets, industrial machinery, and other designated equipment enclosures.
Its space-efficient construction and aerosol-based extinguishing mechanism make it a practical solution for applications where conventional water-based fire suppression methods may be unsuitable.
Advanced Hot Aerosol Fire Suppression Technology
The QRR0.01G Fire Extinguishing Device uses hot aerosol technology to suppress flames by interrupting the chemical chain reaction responsible for combustion. When activated through its specified triggering arrangement, the device releases a concentrated fire-suppressing aerosol into the protected enclosure.
Unlike conventional water-based systems, this technology does not depend on water discharge or pressurized gas cylinders. Its 100 g/m³ specified extinguishing density provides a technical parameter for designing an appropriate suppression arrangement.
Rapid Fire Suppression Response
Featuring a supplier-specified activation/discharge time of ≤15 seconds, the QRR0.01G is designed for rapid aerosol release when triggered.
This fast response can help limit fire development inside appropriately designed and protected enclosures. Actual extinguishing performance depends on enclosure volume, ventilation, installation, and fire conditions.
Designed for Electrical Panels & Sensitive Equipment Enclosures
The Hot Aerosol Automatic Fire Suppression Device is particularly suitable for designated electrical and equipment protection installations.
Electrical cabinets, distribution panels, and control systems can be exposed to overheating, insulation failures, and electrical faults that may develop into fires. When correctly selected and installed, an aerosol fire suppression system can provide an additional layer of protection for these applications.
Installation must account for the device's heat output, required safety clearances, and possible aerosol residue on equipment.
Wide Operating Temperature Range
The QRR0.01G Aerosol Fire Extinguishing Device features a specified operating temperature range of -50°C to +90°C, allowing it to be considered for a variety of demanding industrial environments.
Its compact design is particularly useful in equipment enclosures where installation space is limited and a conventional cylinder-based system may be impractical.
Long Service Life & Compact Construction
Designed with a stated service life of up to 10 years, this aerosol fire suppression device offers long-term standby protection when maintained and stored according to the manufacturer's requirements.
The unit is described by the supplier as maintenance-free, with no pressurized extinguishing cylinder required. Periodic inspection and compliance with the installation instructions remain important for dependable fire protection.
Industrial Applications
The QRR0.01G Automatic Fire Extinguishing Device can be considered for appropriately designed fire suppression installations in:
- Electrical Distribution Panels - Protection of designated electrical enclosures.
- Control Cabinets - Supplementary fire protection for industrial control equipment.
- Server Rooms & Data Centers - Protection of suitable enclosed equipment, subject to system design.
- Telecommunication Equipment - Fire suppression for compatible telecom cabinets.
- Industrial Machinery - Protection of selected enclosed mechanical and electrical systems.
- Automotive Engine Compartments - Applications approved through appropriate installation assessment.
Specifications
| Model | QRR0.01G |
|---|---|
| Product Type | Hot Aerosol Fire Extinguishing Device |
| Suppression Technology | Condensed Aerosol Fire Suppression |
| Operation | Automatic Fire Suppression System |
| Operating Temperature | -50°C to +90°C |
| Service Life | Up to 10 Years |
| Extinguishing Density | 100 g/m³ |
| Activation / Discharge Time | ≤15 Seconds |
| Casing Surface Temperature | Less Than 200°C |
| Thermal Clearance Data | 0.3 m: ≤75°C; 0.12 m: ≤200°C; 0.05 m: ≤400°C |
| Oxidizer Composition | Strontium Nitrate 60%, Potassium Nitrate 20% |
| Pressurized Gas Cylinder | Not Required |
| Maintenance | Supplier-Described as Maintenance-Free |
| Referenced Standards | EN 15276-1:2019 & EN 15276-2:2019 |
| Applications | Electrical Panels, Control Cabinets, Telecom Equipment & Enclosed Machinery |
Package Includes
- 1 × QRR0.01G Hot Aerosol Fire Extinguishing Device
Note:
- Activation Method: Confirm the device's triggering mechanism and any additional components required for automatic operation before installation.
- Installation: Installation and system design should be performed by qualified fire protection personnel according to manufacturer instructions.
- Thermal Safety: The device produces heat during discharge. Observe all specified safety clearances from personnel, combustible materials, and sensitive components.
- Operating Temperature: The stated operating temperature range is -50°C to +90°C.
- Service Life: The stated service life is up to 10 years, subject to manufacturer conditions.
- Standards: EN 15276-1:2019 and EN 15276-2:2019 compliance is claimed by the supplier; supporting certification should be verified before relying on this claim.
- Equipment Compatibility: Aerosol discharge may leave residue. Check suitability for sensitive electrical and electronic equipment.
- Important: This device must be incorporated into a properly designed fire protection arrangement and must not replace required fire alarms, certified extinguishers, or other mandatory safety systems.


Reviews
Clear filtersThere are no reviews yet.